電站測(cè)溫用熱電阻WZP2-221B 供應(yīng)
產(chǎn)品概述
WZP2-221B是一款專為電站及其他工業(yè)環(huán)境設(shè)計(jì)的測(cè)溫用裝配式熱電阻,采用高穩(wěn)定性鉑電阻元件(Pt100分度號(hào)),可直接測(cè)量-200℃至420℃范圍內(nèi)的液體、蒸汽、氣體介質(zhì)及固體表面溫度。其不銹鋼保護(hù)管結(jié)構(gòu)兼具抗腐蝕性與機(jī)械強(qiáng)度,適用于高溫高壓環(huán)境,如火力發(fā)電機(jī)組的主蒸汽管道、輔機(jī)設(shè)備等場(chǎng)景。產(chǎn)品通過(guò)螺紋固定安裝(M27×2規(guī)格),支持與顯示儀表、記錄儀或控制系統(tǒng)配套使用,實(shí)現(xiàn)精準(zhǔn)溫度監(jiān)測(cè)。
核心特點(diǎn)
該熱電阻采用壓簧式感溫元件設(shè)計(jì),有效提升抗振性能,適合存在機(jī)械振動(dòng)的工業(yè)現(xiàn)場(chǎng)。雙支結(jié)構(gòu)可同步輸出兩組獨(dú)立電阻信號(hào),便于冗余控制或數(shù)據(jù)校驗(yàn)。保護(hù)管材料可選1Cr18Ni9Ti不銹鋼或316L,滿足不同介質(zhì)耐腐蝕需求。常溫絕緣電阻≥100MΩ(測(cè)試電壓10-100V DC),確保長(zhǎng)期穩(wěn)定運(yùn)行。熱響應(yīng)時(shí)間根據(jù)插入深度不同可優(yōu)化至90秒以內(nèi),適用于快速溫度變化監(jiān)測(cè)。1815
應(yīng)用領(lǐng)域
廣泛應(yīng)用于電力行業(yè)(如300MW/600MW/1000MW機(jī)組四大管道測(cè)溫)、石油化工設(shè)備、冶金高爐及暖通系統(tǒng)。在超臨界機(jī)組中,其設(shè)計(jì)參數(shù)與管道材質(zhì)(如A335P91/P92、12Cr1MoV等)兼容,通過(guò)同質(zhì)焊接保障安全性。同時(shí)適用于環(huán)保、造紙等非工業(yè)領(lǐng)域的溫度監(jiān)控需求。
Technical Specification
The WZP2-221B thermoelectric resistor is engineered for power plant temperature measurement, featuring Pt100 sensing element with a range of -200°C to 420°C. Its stainless steel sheath (M27×2 threaded fixation) ensures durability under high-pressure conditions. The dual-wire configuration provides redundant output signals for system reliability. Key parameters include:
- Accuracy: Class B tolerance ±(0.30+0.005|t|)℃
- Mechanical Design: Anti-vibration spring-loaded sensing assembly
- Environmental Adaptability: IP65-rated junction box (optional waterproof/explosion-proof variants)
- Installation: Compatible with horizontal/vertical pipelines, minimum insertion depth ≥8×outer diameter
Typical Applications
Ideal for critical temperature monitoring in steam turbines, boiler systems, and auxiliary equipment. The modular design allows easy maintenance and component replacement without process interruption. Customizable length (L) and immersion depth (l) configurations are available to match specific pipeline dimensions.71620
電站測(cè)溫用熱電阻
WZC-130B,WZP-220B,WZP-221B,WZP-230B,WZP-231B,WZP2-220B,WZP2-221B,WZP2-230B,WZP2-231B,WZP-220AB,WZP2-220AB。WZC-220B,WZC-230B,WZC-220AB,WZP-320B,WZP-321B,WZP-330B,WZP-331B,WZP2-320B,WZP2-321B,WZP2-330B,WZP2-330B,WZC-320B,WZC-320B,WZP-420B,WZP-421B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZC-420B,WZC-430B,WZP-420B,WZP-421B,WZP-430B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZP-420B,WZC-430B,WZP-621B,WZP-621AB,WZP-631B,WZP2 -621B,WZP2 -621B,WZP2 -631B,WZP-621B,WZP-631B,WZP-621B,WZP2 -631B,WZP-621AB,WZP2-621AB,WZP-002,WZP-003,WZP-003A,WZCM-201,WZPM-201,WZPM-201,WZP-270S,WZP-26S,WZP-236SB,
量程規(guī)格
名 稱 分度號(hào) 測(cè)溫范圍 ℃ 精度等級(jí) 允 差Δt
鎳鉻-鎳硅熱電偶 K 0~800 2 ±2.5℃或 ±0.75%t
鎳鉻-銅鎳熱電偶 E 0~600 2 ±2.5℃或 ±0.75%t
鉑熱電阻 Pt100 -200~500 B ±(0.3+0.005|t|)
注:t為感溫元件實(shí)測(cè)溫度或?qū)崪y(cè)溫度的值。
□公稱壓力
一般是指在常溫下,保護(hù)管所能承受的靜態(tài)外壓而不破裂,試驗(yàn)壓力一般采用公稱壓力的1.5倍。實(shí)際上,允許工作壓力不僅與保護(hù)管材料、直徑、壁厚有關(guān),而且還與其結(jié)構(gòu)形式、安裝方法、置入深度以及被測(cè)介質(zhì)的流速、種類有關(guān)。
□熱電偶絕緣電阻
常溫絕緣電阻的試驗(yàn)電壓為直流500V。測(cè)量常溫絕緣電阻的大氣條件為:溫度15~35℃,相對(duì)濕度45%RH,大氣壓力86~106kPa。
對(duì)于長(zhǎng)度超過(guò)1米的熱電偶,它的常溫絕緣電阻值與其長(zhǎng)度的乘積應(yīng)不小于100MΩ•m,
即:Rr•L>100MΩ•mL>1m
式中:Rr-熱電偶的常溫絕緣電阻值,MΩ;
L-熱電偶的長(zhǎng)度,m。
對(duì)于長(zhǎng)度等于或不足1米的熱電偶,它的常溫絕緣電阻值應(yīng)不小于100MΩ。
□熱電阻絕緣電阻
常溫絕緣電阻的試驗(yàn)電壓可取直流10~100V任意值,環(huán)境溫度應(yīng)在15~35℃范圍內(nèi),相對(duì)濕度應(yīng)不大于80%RH,常溫絕緣電阻值應(yīng)不小于100MΩ。
□熱電阻允許通過(guò)電流
通過(guò)鉑電阻的測(cè)量電流大不超過(guò)5mA。
|