(中文部分)
WZPK2-126SA隔爆型熱電阻是專為化工行業(yè)特殊工況設計的溫度測量裝置,適用于存在可燃性氣體或粉塵環(huán)境的工業(yè)生產場景。該產品通過特殊結構設計實現(xiàn)隔爆功能,能夠在潛在危險環(huán)境中安全穩(wěn)定地運行,為生產過程提供可靠溫度監(jiān)測解決方案。
產品采用分體式模塊化結構設計,傳感器探頭與接線盒之間通過螺紋連接實現(xiàn)物理隔離。鎧裝元件選用316L不銹鋼材質制造,具備良好的機械強度和耐腐蝕特性,可承受常規(guī)化學介質侵蝕。測溫元件經過特殊封裝工藝處理,在保持靈敏響應的同時提升抗震性能,有效應對管道振動等復雜工況。接線腔體內置多重密封結構,配合防松脫端子設計,確保電氣連接長期穩(wěn)定。
在應用性能方面,該裝置支持-200℃至+500℃寬域溫度測量,常規(guī)條件下測量偏差控制在±1.5℃范圍內。接觸式測溫結構設計可適配多種安裝方式,提供螺紋固定、法蘭連接等標準化接口選擇。產品表面經噴砂鈍化處理,形成均勻防護層,可延緩高溫氧化進程。針對化工裝置常見的介質結晶問題,傳感器前端設計有自清潔斜面結構,減少介質附著對測量精度的影響。
本產品適用于石化精餾塔、反應釜溫度監(jiān)控、輸油管道伴熱系統(tǒng)等場景,在氯堿生產、煤化工、精細化工等領域具有成熟應用經驗。建議用戶根據(jù)具體介質特性選擇適配的護套材質,定期進行絕緣電阻檢測,并在高溫工況下配合保護套管使用以延長設備使用壽命。
(英文部分)
The WZPK2-126SA Explosion-Proof Thermocouple is specifically engineered for temperature measurement in chemical processing environments where combustible gases or dust may be present. Featuring intrinsic safety design, this device ensures reliable operation in hazardous areas while maintaining precise temperature monitoring capabilities.
Constructed with modular architecture, the sensor probe and junction box adopt threaded connection for physical isolation. The armored element utilizes 316L stainless steel with enhanced corrosion resistance, capable of withstanding exposure to common chemical media. Specially encapsulated sensing components deliver responsive measurement while maintaining structural integrity under vibrational conditions. The sealed terminal chamber incorporates multi-layer gaskets and anti-loosening terminals to ensure durable electrical connections.
This instrument provides temperature measurement across a broad range from -200℃ to +500℃, with typical accuracy within ±1.5℃ under standard conditions. Flexible installation options include threaded and flanged connections, accommodating diverse process requirements. The surface-treated housing features uniform protective coating to resist high-temperature oxidation. A self-cleaning tapered tip design minimizes measurement deviations caused by media crystallization or buildup.
Ideal for critical applications including distillation column monitoring, reactor temperature control, and pipeline heating systems in petrochemical plants. The device has demonstrated proven performance in chlor-alkali production, coal chemical processing, and specialty chemical manufacturing. Users are advised to select appropriate sheath materials based on specific media characteristics, perform regular insulation resistance checks, and employ protective sleeves in high-temperature environments to optimize service life.
Maintenance considerations include periodic calibration verification and visual inspection of sealing surfaces. When installed in high-pressure systems, proper torque application during assembly is recommended to maintain structural integrity. The product s design accounts for thermal expansion effects, ensuring stable performance across operational temperature fluctuations.